System |
| |
Carrying Case Size |
58
x 36 x 19 cm (23 x 14 x 7.5 in) approx. |
| |
Weight |
11
kg (24 lb) approx. including typical laptop PC. |
| |
|
|
|
Laptop Personal Computer |
| |
Processor |
266 MHz Pentium min, 1 GHz Pentium rec. |
| |
Memory |
64
MB min, 128 MB rec. |
| |
Free Hard Disc |
100 MB min. |
| |
CDROM |
24X rec. |
| |
Floppy Drive |
3.5 in. 1.44 MB |
| |
PCMCIA Slot |
Type 2 |
| |
Operating System |
Windows 98/Me/NT/2000/XP |
| |
|
Data Acquisition Card |
| |
Type |
National Instruments DAQCard-6024E |
| |
Resolution/Range |
Bits |
Input Range |
Resolution |
| |
|
|
12 |
Fine: ±0.5V,
Coarse: ±10V |
Fine: 0.24 mV,
Coarse: 4.8 mV |
| |
Anti-aliasing filters |
5
kHz, 250 Hz (switchable) |
| |
|
Core System: SC11 Sensor Interface |
| |
Inputs |
|
| |
|
MAG |
3-axis magnetic field sensor (SC20 AC or wideband DC sensor) |
| |
|
VIB1, VIB2,
VIB3 |
3-axis vibration (3 x Wilcoxon 731A) |
| |
|
MIC |
Precision microphone (Brüel & Kjær, 4190/2669L) |
| |
|
AUX |
BNC voltage input, DC coupled, ±10 V range, 100 kOhm input
impedance |
| |
Anti-aliasing filters |
5
kHz, 250 Hz (switchable) |
| |
Power |
100 - 240 V AC, 50 - 60 Hz, 0.25A max |
| |
|
3-axis Magnetic Field Sensor: SC20/AC |
| |
Co-ordinate System |
X,
Y, Z rectangular Cartesian |
| |
Dynamic Range |
40
mG (4 µT) Pk-Pk |
| |
Bandwidth |
5
Hz - 20 kHz |
| |
Noise Limit |
100 nG (10 pT)/root Hz RMS at 50 Hz, 10 nG (1 pT)/root Hz
RMS at 250 Hz, typ. |
| |
Accuracy |
±1
% |
| |
|
3-axis Magnetic Field Sensor: SC20/DC |
| |
Co-ordinate System |
X,
Y, Z rectangular Cartesian |
| |
Dynamic Range |
40
mG (4 µT) Pk-Pk |
| |
Ambient Field Range |
±2
G (±200 µT) |
| |
Bandwidth |
DC
- 5 kHz |
| |
Noise Limit |
DC: 30 µG (3 nT) Pk-Pk typ. (0.0001 - 0.01 Hz) |
| |
|
AC: 1 µG (100 pT)/root Hz RMS typ. at 50 Hz |
| |
Accuracy |
±5
% (after >1hour warm up). (±15 % cold) |
| |
|
Vibration Sensor: Wilcoxon 731A Accelerometer |
| |
Type |
Wilcoxon Research, model 731A |
| |
Dynamic Range |
20
mm/s2 Pk-Pk |
| |
Bandwidth |
0.1 - 500 Hz, 0.1 - 250 Hz (switchable) |
| |
Noise Limit |
7
µm/s2 RMS max. |
| |
|
0.35 µm/s RMS at 1Hz, 0.11 µm/s RMS at 5Hz |
| |
|
0.07 µm RMS at 1Hz, 0.0035 µm RMS at 5Hz |
| |
Accuracy |
±5
% (with gain calibration file) |
| |
|
Acoustic Sensor: B&K 4190/2669L Precision Microphone |
| |
Type |
Brüel & Kjær, Condenser microphone 4190, Pre-amplifier 2669L |
| |
Dynamic Range |
20
dB to 103 dB (in this system) |
| |
Bandwidth |
1.5 Hz - 20 kHz |
| |
Accuracy |
±1
dB 3 Hz - 20 kHz |
| |
|
Acoustic Sensor: Sound Level Meter |
| |
Type |
Radio Shack, Model 33-2050 or 33-4050 |
| |
Dynamic Range |
50
dB to 126 dB |
| |
Accuracy |
±2
dB at 114 dB sound level |
| |
Reference |
0
dB = 20 µPa RMS |
| |
Frequency Response |
dBA and dBC weightings |
| |
Meter Response |
Fast, Slow |
| |
Signal Output |
1.0 V peak into open circuit with full scale meter
deflection at 1 kHz |
| |
Load Impedance |
10
kOhms min. |
| |
Distortion |
<
2 % at 1 kHz and 0.5 V |
| |
|
1-Axis Magnetic Field Sensor: Flux Gate Magnetometer |
| |
Type |
MEDA µMAG-01N |
| |
Ranges |
±20.00, ±200.0, ±2000 mG full scale |
| |
Bandwidth |
0
- 100 Hz |
| |
Accuracy |
±0.5% of full scale |
| |
Linearity |
±0.05% of full scale |
| |
Signal Output |
±2
V full scale |
| |
|
Programs (General) |
| |
Clipping |
Audio/visual indication |
| |
Pause control |
Freeze/resume instrument operation |
| |
Calibration panel |
Add/select sensors, set ranges, calibrate offsets,
microphone self check, add/edit user defined units, set
decimal symbol |
| |
Setup file |
Open/save instrument controls |
| |
Export |
Export results for spreadsheet |
| |
Comment pad |
3
lines |
| |
Print window |
Print current screen display |
| |
Help |
Context help on controls, online help file |
| |
Year 2000 |
All SC11 programs are year 2000 compliant |
| |
|
Oscilloscope |
| |
Channels |
4
(X, Y, Z and A) each with style and position controls |
| |
Divisions |
10
X 10 |
| |
Ranges |
Division Size |
Unit |
| |
|
Magnetic Field |
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
mG |
| |
|
|
10, 20, 50 |
nT |
| |
|
|
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
µT |
| |
|
|
10, 20, 50 |
mA/m |
| |
|
|
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
A/m |
| |
|
Vibration |
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
mg's * |
| |
|
|
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
mm/s2 |
| |
|
Acoustic |
20, 50 |
mPa |
| |
|
|
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
Pa |
| |
|
Voltage |
20, 50 |
mV |
| |
|
|
0.1, 0.2, 0.5, 1, 2, 5, 10 |
V |
| |
|
Resultant
|XYZ| |
Magnetic Field, Vibration, Voltage units |
| |
|
User defined |
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
|
| |
|
Timebase |
0.5, 1, 2, 5, 10, 20, 50, 100, 200 |
ms |
| |
Bandwidth |
5
kHz (0.5 ms/div - 5 ms/div) |
| |
|
250 Hz (10 ms/div - 200 ms/div) |
| |
Digital Meter |
RMS, Peak to Peak (all channels) |
| |
Trigger |
Auto/Manual level, +/- edge, Auto/Manual source |
| |
|
Single Shot |
| |
|
Spectrum Analyser |
| |
Displays |
Waveform (autoscaling), Spectrum |
| |
Amplitude units |
|
| |
|
Magnetic field |
mG, nT, µT, mA/m, A/m |
| |
|
Vibration |
µg's*, mg's*, mm/s2, µm/s, mm/s, nm, µm |
| |
|
Acoustic |
mPa, Pa, dB, dBa, dBC |
| |
|
Voltage |
mV, V |
| |
Amplitude ranges |
0.5, 0.7, 1, 1.5, 2.5, 3.5, 5, 7, 10, 15, 25, 35, 50, 70,
100, 150, 250, log full scale |
| |
Frequency ranges |
20, 25, 30, 40, 50, 60, 80, 100, 125, 150, 200, 250, 300,
400, 500, 600, 800, 1000, 1250, 1500, 2000 Hz full scale |
| |
Number of points |
200, 250, 400, 500, 800, 1000, 1600, 2000 |
| |
Accuracy |
Amplitude: ±5% (not including sensor accuracy or noise) |
| |
|
Frequency: ±0.01% ±0.02 div |
| |
Pan & Zoom Palette |
Pan, zoom and format spectrum display |
| |
Waveform windows |
None, Hanning, Flat top |
| |
Spectrum modes |
RMS, 0-Pk, Pk-Pk, Third Octave |
| |
Combine spectra |
Average/Peak, Max no. spectra |
| |
Cursor modes |
Total RMS between 2 tracking cursors, 10 harmonic cursors |
| |
Specification files |
Create, edit, add & remove. Compare with measurements. |
| |
Capture indicator |
Indicates progress of data acquisition |
| |
Data logging |
Start: Now, At time, Triggered by flat level, Triggered by
spec |
| |
|
Stop: Period, File size, Disk space |
| |
|
Min. time step: 2 minutes |
| |
|
Chart Recorder |
| |
Channels |
4
(X, Y, Z and A) each with style and position controls |
| |
Divisions |
10
X 10 |
| |
Ranges |
as
Oscilloscope, except |
| |
|
|
Division Size |
Unit |
| |
|
Vibration |
10, 20, 50 |
µm/s |
| |
|
|
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
mm/s |
| |
|
|
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 |
µm |
| |
|
Timebase |
0.5, 1, 2, 5, 10, 20, 50 |
s |
| |
|
|
50
points/div |
| |
Chart length |
200 div. max. (1.6 minutes - 2.7 hours) |
| |
Bandwidth |
(Bandwidth is reduced in some modes) |
| |
|
Magnetic field
(SC20/DC sensor) |
DC
- 250 Hz |
| |
|
Magnetic field
(SC20/AC sensor) |
5
Hz - 250 Hz |
| |
|
Vibration |
0.01 Hz - 250 Hz |
| |
|
Acoustic
(Precision Microphone) |
1.5 Hz - 250 Hz |
| |
|
Acoustic (SLM) |
20
Hz - 250 Hz |
| |
|
Voltage |
DC
- 250 Hz |
| |
Chart palette |
Pan, zoom, format, reset and clear chart |
| |
Chart modes |
Waveform, RMS, Peak to Peak, Waveform ext. LF, Narrow band
RMS, Narrow band Pk-Pk. |
| |
Update modes |
Strip chart, scope chart, sweep chart |
| |
Bandwidth display |
XYZ/A upper/lower for all modes except narrow band |
| |
Narrow band filter |
Centre frequency, f0 range: 1 Hz - 250 Hz
Accuracy: ±1% within pass band, f0 ± 3%
Attenuation: 60 dB min. in stop band, f0 ±
20% |
| |
Markers |
Time, text string |
| |
Data logging |
Start: Now, At time, Triggered
Stop: Period, File size, Disk space
Time step: Whole number of points (0.01 s at 0.5 s/div) |
| |
| *
g is the acceleration due to gravity |
|