SC20 Product Description
The SC20 is the latest magnetic field cancelling
system from Spicer Consulting, introduced in 2004. The SC20 is the
recommended system for cancelling DC fields, large fields and, as the
SC-20FAST, the 9kHz fields generated
by wafer transport robots in 300mm fabs.
|
The SC20 Magnetic Field Cancelling
System. Click on the image above to open a window with an interactive
tour.
|
The SC20 has been designed to be largely
backwards compatible with the SC12. The systems use the same
operating principle and installations as described on the SC12
Product Description page. The SC20 is plug compatible with the
SC12 field cancelling cables to enable easy upgrade of
SC12 installations to the SC20.The
SC20 control unit is not plug compatible with the
SC12 magnetic field sensors.
The SC20 case is larger than the
SC12 enabling more powerful amplifiers, more cancelling range and
easier rack mounting. It will install into a standard 19inch rack 3U space with the
rack mount brackets fitted. The SC20 output amplifiers provide 60%
more cancelling range than the SC12 and they will withstand an
output short circuit or full scale overload indefinitely without degradation. (The
SC12 amplifiers are protected with thermal fuses which may degrade
if subjected to long term overload.)
The front panel display has been simplified and upgraded to display
the magnetic field amplitude of all three field axes continuously as well as the
magnitude of the total field vector. The display units are switchable between
milligauss and microtesla and the display can be AC-RMS or
Incremental DC when the SC20 wideband sensor is
used. The BNC connectors for monitoring the realtime field with a
scope have been moved to the front panel for easier access.
To futher enhance the "set and forget" performance, the set up
controls which affect cancelling have been located behind a secure drop down front
panel. This is to prevent tampering or accidental adjustment of the controls in
unattended installations.
The system can provide AC or DC
cancelling depending on the sensors installed. It recognises the sensors used and
selects the internal filters to use. The sensor mixer function (an add-on box with the
SC12) is built into the SC20 and becomes active
when two sensors are plugged in.
The SC20 includes a system
interface enabling the SC20 monitor to be connected, allowing
remote monitoring of the SC20 status and measured field levels.
|